Page view 26
23
D
ESIGN
S
PECIFICATIONS
MS1890
D
ESIGN
S
PECIFICATIONS
E
LECTRICAL
Input Voltage: 5.0VDC ± 0.25V
Peak = 2 W (Typical)
Operating = 1.65 W (Typical)
Power:
Idle / Standby = 800 mW (Typical)
Peak = 400 mA (Typical)
Operation =
330 mA (Typical)
Current:
Idle / Standby = 160 mA (Typical)
DC Transformer: Class 2; 5.2VDC @ 1A
For Regulatory Compliance information, see pages 36 - 38.
E
NVIRONMENTAL
Operating = 0°C to 50° (32° to 122°F)
Temperature:
Storage = -40°C to 60°C (-40°F to 140°F)
Humidity: 0% to 95% Relative Humidity, Non-Condensing
Light Levels: Up to 100,000 Lux (9,290 Footcandles)
Shock: Designed to withstand 2 m (6.5 ft.) drops
Contaminants: Dust tight and protected against splashing water.
Ventilation: None required
IP Rating: IP54
Specifications are subject to change without notice.